The stirrer is ideal stir tool for laboratory uses.Adjustable heating temperature, stirring times and stirring speeds. Automatic hold setting temperature through incidental temperature probe. Maximum Stirring Volume: 2000mL , Stirring Speed: 0~2500rpm . Timer: 999 minutes
Dead Weight calibration checks help maintain the accuracy of the torque measuring system on all Viscometers. Quickly determine the condition of bearings and the accuracy of torsion spring setting. Kit includes support bracket, spool for bob-shaft, 5 metric weights, spare thread, instructions, and case.
The Dynamic Linear, Swell Meter , High Temperature helps determine shale hydration or dehydration by measuring the increase or decrease in length over time of reconstituted or intact shale core. Measuring Units 2 head,Measuring Range:0-20mm Working Temperature:0-300℃(572℉)
The Filter Presse is the most effective means of determining the filtration properties of drilling muds and cement slurries. 6 Unit 1000ml Cells, Working pressure is 100 psig and the filtering area is 7.1-in2.
The Aging Cell with Teflon Liner is a 500 ml, Type 316 / 304 stainless steel pressure vessel, certified for 600℉ (315℃) and 2500 psi (17,237 kPa) RIGCHINA aging cells are designed to be used with RIGCHINA Roller Oven. It be found in API 13B-1 and 13I.
The Marsh Funnel Viscometer is a rugged, easy to operate instrument that is used for making rapid, on the spot measurements of drilling mud viscosity. The Marsh Funnel readings are only general measurements, but the frequent reporting of the Marsh Funnel Viscosity will alert the mud engineer to sudden changes in the mud viscosity that could require corrective action.
The HTHP Swell Meter is designed to simultaneously test up to four drilling fluids (expandable to eight) on a representative shale sample for extended periods of time at temperatures up to 150℃(302°F). Measuring Units 2 head
The Filter Presse is the most effective means of determining the filtration properties of drilling muds and cement slurries. 6 Unit 2000ml Cells, Working pressure is 100 psig and the filtering area is 7.1-in2.
These stirrers are ideal stir tool for laboratory uses. Adjustable heating temperature, stirring times and stirring speeds. Automatic hold setting temperature through incidental temperature probe. Maximum Stirring Volume: 2000mL , Stirring Speed: 0~2500rpm , Timer: 999 minutes ,Temperature Range: up to 300℃
The Aging Cell, Double Capped, 500 mL, Type 316 / 304 stainless steel pressure vessel, certified for 600℉ (315℃) and 2500 psi (17,237 kPa) RIGCHINA aging cells are designed to be used with RIGCHINA Roller Oven. It be found in API 13B-1 and 13I.
The Marsh Funnel Viscometer is a rugged, easy to operate instrument that is used for making rapid, on the spot measurements of drilling mud viscosity. The Marsh Funnel readings are only general measurements, but the frequent reporting of the Marsh Funnel Viscosity will alert the mud engineer to sudden changes in the mud viscosity that could require corrective action.
The HTHP Swell Meter is designed to simultaneously test up to four drilling fluids (expandable to eight) on a representative shale sample for extended periods of time at temperatures up to 150℃(302°F). Measuring Units 1 head