The Permeability Plugging Apparatus (PPA) is designed to provide accurate simulation and measurement of down-hole static filtration. Pressure rating: 5,000 psig (34,473 kPa) Temperature rating: 500°F (260°C)
The Model RCMB Series Mud Balance provides a simple, practical method for accurate determination of fluid density. Measuring Range (2 Scales):5.8-24 lb/gal (0.7-2.9 gms/cm3 Specific Gravity) Material: Stainless Steel
Low Pressure, Low Temperature (LPLT) Filter Presses are the most effective means of determining the filtration properties of drilling muds and cement slurries. 500ml Sample Cell, Working pressure is 100 psig and the filtering area is 7.1-in2. CO2 Balloon Pressure Assembly
The Mud Testing Kit is designed to provide all necessary drilling fluid testing equipment required for field testing of drilling fluids according to API Recommended Practice 13B-1. All kits may be custom designed to meet customers' individual specifications. Special requests and suggestions are always welcome.
This hand driven centrifuge is perfect for field use. The simple compact design eliminates complicated operation and assures years of dependable service. Centrifuge, Hand Crank, 2 Place Head and Shields for 100 mL Tubes Hand Driven – Max Speed is 2000 RPM.
Standard crush or non-destructive compressive-strength tests are performed on cement slurry samples under simulated downhole pressure and temperature conditions to determine the initial set time and the wait-on-cement (woc) time. Temperature: up to 600℉ (315℃) Pressure: up to 5,950psi (41mPa) 4 cube mold set (Small Cabinet)
The mixers are recommended for use in general purpose mixing of drilling fluids in preparation for laboratory tests of mud materials. Speeds: 0-18,000 RPM, No of Speeds: 3(Low, Medium, High). 1 spindle,Volume: 1500ml
The Model RCMB Series Mud Balance provides a simple, practical method for accurate determination of fluid density. Measuring Range(2 Scales): (5.83-26lb/gal) / 0.7-3.1 gms/cm3 (Specific Gravity) Material: Stainless Steel
We use viscometers that routinely measure viscosity as a function of shear rate together with rheometers that can characterize the solid-like properties of the same material.API Tests Pre-programmed,6 presets 600, 300, 200, 100, 6, 3 Push button design for easy operation and better control
The High Temperature Atmospheric Swell Meter (HASM) helps determine shale hydration or dehydration by measuring the increase or decrease in length over time of reconstituted or intact shale core. Measuring Units 1 head,Measuring Range:0-20mm Working Temperature:0-300℃(572℉)