HFP-71C
RIGCHINA
171-02C
HPHT Filter Press Model HFP-71C,Double Capped Cell for Cement Screens
The HTHP (High Temperature, High Pressure) Filter Press is designed for testing drilling fluids under elevated temperatures and pressures. The unit simulates various downhole conditions and provides a reliable method for determining the effectiveness of the material being tested.
The High Pressure-High Temperature (HPHT) Filter Presses are an efficient means of evaluating the filtration properties of drilling muds at high temperatures and pressures. The cells have a filtering area of 3.5 in2 and can be operated at pressures up to 900 psi with the compact, easily attached CO2 pressuring unit provided.
The Model HFP-42 Series HTHP Filter Press is equipped with a 175 mL sample cell and the working temperatures above 350°F (177°C), making it ideal for laboratory use. Also included is a regulator manifold system for connecting to bottled nitrogen for higher pressures up to1, 800 PSI (12,400 kPa
The Model HFP-71 Series HTHP Filter Press is equipped with a 500 mL sample cell and the working temperatures above 500°F (260°C), making it ideal for laboratory use. Also included is a regulator manifold system for connecting to bottled nitrogen for higher pressures up to1, 800 PSI (12,400 kPa)
Filter Press HTHP Specification | ||
Part No. | Model | Specification |
170-02 | HFP-42 | Single Capped Cell for Filter Paper
The digital system is accurate and controllable. Maximum Temperature : 350℉ (177℃) Maximum Pressure Cell: 1800 psig (12.4 MPa) Maximum Backpressure: 750 psig (5.17 MPa) Sample Cell Volume: 175 ml Receiver Volume: 15 ml Filtering Area: 3.5 in2 (22.58 cm2) Pressure Connection: Nitrogen or Carbon Dioxide Heating Capacity :400 Watts Power Requirement: 115/230 VAC, Frequency 50/60 Hz Size: 320×320×650 mm Weight:36kg |
170-02D | HFP-42D | Double Capped Cell for Ceramic Disks.
The digital system is accurate and controllable. Maximum Temperature : 350℉ (177℃) Maximum Pressure Cell: 1800 psig (12.4 MPa) Maximum Backpressure: 750 psig (5.17 MPa) Sample Cell Volume: 175 ml Receiver Volume: 15 ml Filtering Area: 3.5 in2 (22.58 cm2) Pressure Connection: Nitrogen or Carbon Dioxide Heating Capacity :400 Watts Power Requirement: 115/230 VAC, Frequency 50/60 Hz Size: 320×320×650 mm Weight:36kg |
171-02 | HFP-71 | Single Capped Cell for Filter Paper
The digital system is accurate and controllable. Maximum Temperature : 500℉ (260℃) Maximum Pressure Cell: 1800 psig (12.4 MPa) Maximum Backpressure: 750 psig (5.17 MPa) Sample Cell Volume: 500 ml Receiver Volume: 100 ml Filtering Area: 3.5 in2 (22.58 cm2) Pressure Connection: Nitrogen or Carbon Dioxide Heating Capacity :800 Watts Power Requirement: 115/230 VAC, Frequency 50/60 Hz Size: 720×440×340 mm |
171-02C | HFP-71C | Double Capped Cell for Cement Screens
The digital system is accurate and controllable. Maximum Temperature : 500℉ (260℃) Maximum Pressure Cell: 1800 psig (12.4 MPa) Maximum Backpressure: 750 psig (5.17 MPa) Sample Cell Volume: 500 ml Receiver Volume: 100 ml Filtering Area: 3.5 in2 (22.58 cm2) Pressure Connection: Nitrogen or Carbon Dioxide Heating Capacity :800 Watts Power Requirement: 115/230 VAC, Frequency 50/60 Hz Size: 720×440×340 mm |
171-02D | HFP-71D | Double Capped Cell for Ceramic Disks.
The digital system is accurate and controllable. Maximum Temperature : 500℉ (260℃) Maximum Pressure Cell: 1800 psig (12.4 MPa) Maximum Backpressure: 750 psig (5.17 MPa) Sample Cell Volume: 500 ml Receiver Volume: 100 ml Filtering Area: 3.5 in2 (22.58 cm2) Pressure Connection: Nitrogen or Carbon Dioxide Heating Capacity :800 Watts Power Requirement: 115/230 VAC, Frequency 50/60 Hz Size: 720×440×340 mm |
HPHT Filter Press Model HFP-71C,Double Capped Cell for Cement Screens
The HTHP (High Temperature, High Pressure) Filter Press is designed for testing drilling fluids under elevated temperatures and pressures. The unit simulates various downhole conditions and provides a reliable method for determining the effectiveness of the material being tested.
The High Pressure-High Temperature (HPHT) Filter Presses are an efficient means of evaluating the filtration properties of drilling muds at high temperatures and pressures. The cells have a filtering area of 3.5 in2 and can be operated at pressures up to 900 psi with the compact, easily attached CO2 pressuring unit provided.
The Model HFP-42 Series HTHP Filter Press is equipped with a 175 mL sample cell and the working temperatures above 350°F (177°C), making it ideal for laboratory use. Also included is a regulator manifold system for connecting to bottled nitrogen for higher pressures up to1, 800 PSI (12,400 kPa
The Model HFP-71 Series HTHP Filter Press is equipped with a 500 mL sample cell and the working temperatures above 500°F (260°C), making it ideal for laboratory use. Also included is a regulator manifold system for connecting to bottled nitrogen for higher pressures up to1, 800 PSI (12,400 kPa)
Filter Press HTHP Specification | ||
Part No. | Model | Specification |
170-02 | HFP-42 | Single Capped Cell for Filter Paper
The digital system is accurate and controllable. Maximum Temperature : 350℉ (177℃) Maximum Pressure Cell: 1800 psig (12.4 MPa) Maximum Backpressure: 750 psig (5.17 MPa) Sample Cell Volume: 175 ml Receiver Volume: 15 ml Filtering Area: 3.5 in2 (22.58 cm2) Pressure Connection: Nitrogen or Carbon Dioxide Heating Capacity :400 Watts Power Requirement: 115/230 VAC, Frequency 50/60 Hz Size: 320×320×650 mm Weight:36kg |
170-02D | HFP-42D | Double Capped Cell for Ceramic Disks.
The digital system is accurate and controllable. Maximum Temperature : 350℉ (177℃) Maximum Pressure Cell: 1800 psig (12.4 MPa) Maximum Backpressure: 750 psig (5.17 MPa) Sample Cell Volume: 175 ml Receiver Volume: 15 ml Filtering Area: 3.5 in2 (22.58 cm2) Pressure Connection: Nitrogen or Carbon Dioxide Heating Capacity :400 Watts Power Requirement: 115/230 VAC, Frequency 50/60 Hz Size: 320×320×650 mm Weight:36kg |
171-02 | HFP-71 | Single Capped Cell for Filter Paper
The digital system is accurate and controllable. Maximum Temperature : 500℉ (260℃) Maximum Pressure Cell: 1800 psig (12.4 MPa) Maximum Backpressure: 750 psig (5.17 MPa) Sample Cell Volume: 500 ml Receiver Volume: 100 ml Filtering Area: 3.5 in2 (22.58 cm2) Pressure Connection: Nitrogen or Carbon Dioxide Heating Capacity :800 Watts Power Requirement: 115/230 VAC, Frequency 50/60 Hz Size: 720×440×340 mm |
171-02C | HFP-71C | Double Capped Cell for Cement Screens
The digital system is accurate and controllable. Maximum Temperature : 500℉ (260℃) Maximum Pressure Cell: 1800 psig (12.4 MPa) Maximum Backpressure: 750 psig (5.17 MPa) Sample Cell Volume: 500 ml Receiver Volume: 100 ml Filtering Area: 3.5 in2 (22.58 cm2) Pressure Connection: Nitrogen or Carbon Dioxide Heating Capacity :800 Watts Power Requirement: 115/230 VAC, Frequency 50/60 Hz Size: 720×440×340 mm |
171-02D | HFP-71D | Double Capped Cell for Ceramic Disks.
The digital system is accurate and controllable. Maximum Temperature : 500℉ (260℃) Maximum Pressure Cell: 1800 psig (12.4 MPa) Maximum Backpressure: 750 psig (5.17 MPa) Sample Cell Volume: 500 ml Receiver Volume: 100 ml Filtering Area: 3.5 in2 (22.58 cm2) Pressure Connection: Nitrogen or Carbon Dioxide Heating Capacity :800 Watts Power Requirement: 115/230 VAC, Frequency 50/60 Hz Size: 720×440×340 mm |